摘    要:分析低温管道保冷层的失效及被破坏的原因,主要是在保冷隔汽层设置及施工方面存在缺陷,造成供冷管路金属表面水渍侵袭、锈蚀严重,致使保冷层的功能荡然无存,也使得冷损失加大、能量白白浪费。介绍保冷管道的防水、防潮、隔汽的不同物理意义。提出将保冷管道隔汽层的连续性和严密性作为重点改进方向。

关 键 词:空调  管道保冷层  隔汽层  改进措施  冷凝水

Failure reasons and their improvement measures on insulation layer of cool pipe
Li Shaoji Shu Haijing. Failure reasons and their improvement measures on insulation layer of cool pipe[J]. Refrigeration and Air-conditioning, 2012, 0(5): 97-99
Authors:Li Shaoji Shu Haijing
Affiliation:Li Shaoji Shu Haijing(Shandong Jianzhu University)
Abstract:Failure and damaged reasons on insulation layer of low-temperature pipe are analyzed.They are the installing and constructional deficiency of vapor barrier,which cause the water-damaged attack and rust-eaten on the metal surface of cool pipe,the failure of cold insulation layer and the serious refrigerating loss.In addition,the physical meanings of the cool pipe waterproof,damp-proof and vapor barrier are introduced respectively.The continuity and tightness of vapor barrier of cool pipe are considered as the very important improvement direction.
Keywords:air-conditioning  insulation layer of cool pipe  vapor barrier  improvement measure  condensate