摘    要:靠近电源点的送端系统电压稳定性较好,但对于轻负荷地区电网电压和功率因数会偏高,难以达到电网考核的标准。结合宿迁电网分析了靠近电源点的地区电网无功电压情况,从变压器的配置、无功平衡以及小电厂和用户无功考核等方面指出了目前电网存在的问题,并提出的一些解决措施和建议。

关 键 词:地区电网  电压控制  无功平衡

Analysis of Reactive Power Voltage near the Power Source
MI Zuo-wei,XIA Mei-hong.Analysis of Reactive Power Voltage near the Power Source[J].Power Capacitor $ Reactive Power Compensation,2009,30(5):14-16,57.
Authors:MI Zuo-wei  XIA Mei-hong
Abstract:The voltage stability of regional grid near the power source is better.However,the voltage and power factor in light load area will be high,which difficult to meet the power grid criteria.This paper analyzes the voltage and reactive power control in the Suqian district.From the point view of transformer choice,reactive power balance,reactive power criteria of small power plant and customers,points out problems existing at present power network,and proposes some measures and suggestions.
Keywords:Regional grid  Voltage control  Reactive power balance