摘    要:按照JJG 814-2015规定,自动电位滴定仪需进行电计示值误差和仪器示值误差检定,本文例举对这两项检定结果进行不确定度评定,供相关人员参考。

关 键 词:不确定度评定  自动电位滴定仪  电计示值误差  仪器示值误差

Evaluation of Uncertainty about Measurement of Indication Error of Automatic Potentiometric Titrator
NIE Yujia,TENG Heng. Evaluation of Uncertainty about Measurement of Indication Error of Automatic Potentiometric Titrator[J]. Metrology and Measurement Technique, 2020, 47(1): 94-96
Authors:NIE Yujia  TENG Heng
Abstract:According to JJG 814-2015,the automatic potentiometric titrator needs to carry out the verification of the indicating value error of the electrometer and the indicating value error of the instrument. This paper gives an example to evaluate the uncertainty of these two verification results for the reference of relevant personnel.
Keywords:evaluation of uncertainty  Automatic Potentiometric Titrator  the indication error of the electrometer  the indication error of the instrument