Measurement of the subcriticality of power-stressed reactors with an analog reactimeter
Authors:V V Bondarenko  B G Dubovskii  R É Bagdasarov  V A Lititskii  A N Efeshin
Abstract:Conclusions A technique has been developed for measuring the effects of reactivity in a subcritical reactor with an analog reactimeter. It is based on the compensation of the current applied to the reactimeter input from the neutron detector. The compensation of current produced by neutrons of the subcritical multiplying assembly formalizes the algorithm for reactivity calculation, making it an adequate model of a reactor with a source and making it possible to determine the subcriticality without prior entry into the critical state. In this case the measurements are made in the presence of neutron sources characteristic of power-stressed reactors. The regular devices of the control and safety system could be used to produce unsteady variation of the neutron flux.All of this permits the proposed method to be extended to zero-power reactors and to power-stressed reactors. Once the subcriticality has been measured an analog of the neutron source is introduced into the reactimeter. This instrument measures the effects of reactivity in the subcritical state without the reactor being previously put into the critical state, monitors the entry of the reactor into the critical state by checking the reactivity, and makes all the measurements usually made with analog reactimeters. If the intensity of the source does not change during measurements (5–10 min) when chambers sensitive to gamma rays (e.g., KNK-56 chambers) are used as neutron-flux detectors, then the accuracy of gamma-ray compensation does not affect the results of the measurements.Translated from Atomnaya Énergiya, Vol. 45, No. 5, pp. 375–376, November, 1978.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号