Measurement of heat transfer coefficients for direct contact condensation in core makeup tanks using holographic interferometer
Authors:Seong Hun Ju   Hee Cheon No  Franz Mayinger
Abstract:The present work is to improve our understanding and analysis of direct contact condensation on the gravity injection of CMTs and to measure the heat transfer coefficients around steam bubbles using the holographic interferometer and high speed camera. The condensation regime map associated with the downward injection of steam into water through the steam pipe is investigated to understand the mechanism of the direct contact condensation. The present map shows that the boundary of chugging and subsonic jetting with the larger diameter pipe is shifted to the larger steam mass flux. Steam cavity mode, not found in the literature, and the unique mode of downward injection for the present geometry, is observed at the low subcooled water temperature. With the holographic interferometry and the high speed camera, the heat transfer mechanism for the direct contact condensation in CMTs is understood and the heat transfer coefficients are measured.
Keywords:Direct contact condensation   Core makeup tank   Heat transfer coefficients   Holographic inteferometer   High speed camera