摘    要:建立了电感耦合等离子体原子发射光谱法测定氧化铁皮中铅、铬、镉的新方法。样品采用盐酸分解,以高纯铁进行基体匹配。铅、铬、镉的检出限分别0.0008%、0.00012%、0.00008%,最大相对标准偏差为8.33%,方法回收率介于92.0%-110%之间。

关 键 词:氧化铁皮        ICP-AES

Determination of Pb, Cr and Cd in mill scale by inductively coupled plasma atomic emission spectrometry
Cai Lu-xin,Pu Xu-li,Zou Jian-long,Dong Qing-mu,Wang Hong-hui. Determination of Pb, Cr and Cd in mill scale by inductively coupled plasma atomic emission spectrometry[J]. Fujian Anal Ysis & Testing, 2011, 20(6): 54-56
Authors:Cai Lu-xin  Pu Xu-li  Zou Jian-long  Dong Qing-mu  Wang Hong-hui
Affiliation:(Inspection and Quarantine TechnologyCenter ofXiamen Entry-Exit Inspection and Quarantine Bureau,Xiamen Fujian,361026,China)
Abstract:A new method has been developed for the determination of Pb,Cr and Cd in mill scale by inductively coupled plasma-atomic emission spectrometry(ICP-AES).The samples were digested by HCl(1+1)and determined by ICP-AES with with matrix matching.The detection limits of the method for Pb,Cr and Cd were 0.0008%,0.00012% and 0.00008%,respectively,and the maxium RSD was 8.33%,and the recovery of the method was in the range of 92.0% to 110%.