摘    要:泵前加药可能出现不能加入的现象 ,理论分析其产生的原因可知 :合理的加药系统水封高度和管路设计是关键 .

关 键 词:水泵  混凝  扬程  流量
修稿时间:1999-06-30

Disussion on the Problem That Coagulant Can't by Carried to Water When Coagulant is Hoped to Add in front of Pump in Coagulation
Guan Xijun. Disussion on the Problem That Coagulant Can't by Carried to Water When Coagulant is Hoped to Add in front of Pump in Coagulation[J]. Journal of Qingdao Technological University, 2000, 21(3): 15-18
Authors:Guan Xijun
Abstract:Coagulant can not be carride to water when coagulant is hoped to add in front of pump in coagulation. The keys to solve the problem are the suitable height of the system's water sealing box and the reasonable design of pipeline.A few main points mentioned in the paper are for a designer's reference