首页 | 本学科首页   官方微博 | 高级检索  
     

200MW汽轮机大修后的振动故障分析
引用本文:吕传新. 200MW汽轮机大修后的振动故障分析[J]. 湖北电力, 2003, 27(3): 47-48,51
作者姓名:吕传新
作者单位:武汉钢电股份有限公司,湖北,武汉,430082
摘    要:汽轮机大修后在启动过程中的振动故障要仔细分析,避免误判断。对于因为轴封动静碰磨而产生的机组振动,通过在低转速下的磨轴封的措施是可行的,但是必须采用适当的转速,监视机组在启动过程中的振动,防止发生大轴弯曲。

关 键 词:200MW汽轮机 轴承基座 转子 汽缸 振动 故障分析 检修
文章编号:1006-3986(2003)03-0047-02

Analysis of Vibration Fault of 200 MW Turbine after Overhaul
LU Chuan-xin. Analysis of Vibration Fault of 200 MW Turbine after Overhaul[J]. Hubei Electric Power, 2003, 27(3): 47-48,51
Authors:LU Chuan-xin
Abstract:After overhaul vibration fault of 200MW turbine occurring during the start-up process should be analyzed caref ully to avoid incorrect diagnosis.The vibration caused by the impact wear betwee n the moving and static gland seal could be eliminated by means of abrading the gland seal at lower rotating speed.However,the proper speed and vibration monito ring measures were necessary to prevent the shaft from bending.
Keywords:turbine  bearing vibration  vibration analysis