首页 | 本学科首页   官方微博 | 高级检索  
     


Operation of the ATLAS muon drift-tube chambers at high background rates and in magnetic fields
Authors:Horvat   S. Khartchenko   D. Kortner   O. Kotov   S. Kroha   H. Manz   A. Mohrdieck-Mock   S. Nikolaev   K. Richter   R. Stiller   W. Valderanis   Ch. Dubbert   J. Rauscher   F. Staude   A.
Affiliation:Inst. Ruddej er Boskovic, Max-Planck-Inst. fur Phys., Zagreb, Croatia;
Abstract:In the ATLAS muon spectrometer, large drift-tube chambers are used for precision tracking. The chambers will be operated at a high neutron and /spl gamma/ background resulting in count rates of up to 500 Hz cm/sup -2/ corresponding to 300 kHz per tube. The spatial resolution of the drift tubes is degraded from 82 /spl mu/m without background to 108 /spl mu/m at 500 Hz cm/sup -2/ background count rate. Due to afterpulsing in the Ar/CO/sub 2/ gas mixture used in the drift tubes, ionizing radiation causes more than one hit in a tube within the maximum drift time of about 800 ns which is expected for magnetic field strengths around 1.2 T. In order to limit the count rate, the drift tubes are read out with an artificial dead time of 790 ns which causes an efficiency loss of 23% at a rate of 300 kHz per tube. The space-to-drift-time relationship of the tubes varies with background rate, temperature, and magnetic field strength. The mean magnetic field strength in a muon chamber is 0.4 T on the average, but may vary by up to 0.4 T within a chamber. The space-to-drift-time relationship must therefore be determined in short time intervals with an accuracy better than 20 /spl mu/m using muon tracks and applying corrections for measured magnetic field variations.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号