基于高斯过程的钢-木混合结构刚度比全局敏感性分析
引用本文:罗琪 何敏娟 李征. 基于高斯过程的钢-木混合结构刚度比全局敏感性分析[J]. 土木工程学报, 2021, 54(8): 56-66
作者姓名:罗琪 何敏娟 李征
作者单位:同济大学, 上海 200092
摘    要:在钢-木混合结构中,轻木剪力墙和钢框架的刚度比是影响结构性能的重要参数.为了研究不同楼层刚度比对结构响应的影响程度,采用基于高斯随机过程的回归模型,进行了基于方差的全局敏感性分析.在分析中,建立了 180个不同钢-木混合结构,以不同楼层刚度比作为影响因素,考虑了 4种不同的结构响应,并以主效应和全效应作为敏感性的评价指...

关 键 词:钢-木混合结构  刚度比  高斯过程  基于方差  全局敏感性分析

Global sensitivity analysis of wall-to-frame stiffness ratio of timber-steel hybrid structure based on Gaussian-process
Luo Qi He Minjuan Li Zheng. Global sensitivity analysis of wall-to-frame stiffness ratio of timber-steel hybrid structure based on Gaussian-process[J]. China Civil Engineering Journal, 2021, 54(8): 56-66
Authors:Luo Qi He Minjuan Li Zheng
Affiliation:Tongji University, Shanghai 200092, China
Abstract:For the timber-steel hybrid structure, the stiffness ratio of lightweight timber shear walls over the steel frame is an important parameter which affects the seismic performance of a structure. In order to study the influence of stiffness ratios of different stories on structural response, a regression model based on Gaussian stochastic process was employed to conduct variance-based global sensitivity analysis. In the analysis, 180 different timber-steel hybrid structures were established, the stiffness ratios of various stories were treated as factors, four different structural responses were taken into account, and the main effect and the total effect were adopted as sensitivity indices. The results indicated that, the fundamental period could be predicted with excellent accuracy using the Gaussian process model, and the coefficient of determination could reach over 0.99. The stiffness ratio of a story may significantly impact the maximum inter-story drift when the stiffness of the steel frame of a story changes obviously. The difference between total effect and main effect was greater than 0.3, indicating that the relationship between the maximum inter-story drift and the stiffness ratios has the apparent nonlinear feature. The maximum acceleration was the most sensitive to the stiffness ratio of the second story. The sensitivity of the base shear to the stiffness ratios varied with the change of the seismic hazard levels. The fundamental period was more sensitive to the stiffness ratios of lower part of the structure, and the difference between total effect and main effect was less than 0.001, implying that the fundamental period was mainly governed by the main effect of stiffness ratios.
Keywords:timber-steel hybrid structure   wall-to-frame stiffness ratio   Gaussian-process   variance-based   global sensitivity analysis  