Efficiency of PGDC electric filters behind a rotary furnace for firing dolomite |
| |
Authors: | G M A Aliev I D Minaev |
| |
Affiliation: | (1) NIIOGAZ, USSR;(2) Dokuchaev Flux-Dolomite Combine, USSR |
| |
Abstract: | Conclusions Tests on electric filters type PGDC for extracting highly ohmic dolomite dust showed that when the rotary furnace is burning natural gas, and the flue gas velocity is 1.2–1.3 m/sec, the apparatus operates reliably with an efficiency of at least 90.0%When sulfurous fuel oil grade-100 (containing 3.2–3.5% sulfur) is being burned, the efficiency of the electric filter drops on the seventh day of operation to 85.6%, which is due to the appearance in the electric filter to a marked back corona. It is necessary to make further investigations to increase the efficiency of the equipment.Translated from Ogneupory, No. 3, pp. 15–17, March, 1971. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|