首页 | 本学科首页   官方微博 | 高级检索  
     


Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses
Authors:Hori Yasuaki  Hirai Akiko  Minoshima Kaoru
Affiliation:National Institute of Advanced Industrial Science and Technology, Umezono, Tsukuba, Ibaraki, Japan. y‐hori@aist.go.jp
Abstract:A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of 10(-6). The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as 1.1×10(-6).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号