Measurement and analysis of neutron and gamma-ray emission rates,other fusion products,and power in electrochemical cells having Pd cathodes |
| |
Authors: | David Albagli Ron Ballinger Vince Cammarata X. Chen Richard M. Crooks Catherine Fiore Marcel P. J. Gaudreau I. Hwang C. K. Li Paul Linsay Stanley C. Luckhardt Ronald R. Parker Richard D. Petrasso Martin O. Schloh Kevin W. Wenzel Mark S. Wrighton |
| |
Affiliation: | (1) Present address: Department of Chemistry, Massachusetts Institute of Technology, 02139 Cambridge, Massachusetts;(2) Present address: Plasma Fusion Center, Massachusetts Institute of Technology, 02139 Cambridge, Massachusetts;(3) Department of Nuclear Engineering, Massachusetts Institute of Technology, 02139 Cambridge, Massachusetts;(4) Department of Materials Science and Engineering, Massachusetts Institute of Technology, 02139 Cambridge, Massachusetts |
| |
Abstract: | Results of experiments intended to reproduce cold fusion phenomena originally reported by Fleischmann, Pons, and Hawkins are presented. These experiments were performed on a pair of matched electrochemical cells containing 0.1×9 cm Pd rods that were operated for 10 days. The cells were analyzed by the following means: (1) constant temperature calorimetry, (2) neutron counting and γ-ray spectroscopy, (3) mass spectral analysis of4He in effluent gases, and4He and3He within the Pd metal, (4) tritium analysis of the electrolyte solution, and (5) x-ray photoelectron spectroscopy of the Pd cathode surface. Within estimated levels of accuracy, no excess power output or any other evidence of fusion products was detected. |
| |
Keywords: | Fusion cold fusion palladium excess heating |
本文献已被 SpringerLink 等数据库收录! |
|