摘    要:本文针对飞来峡水电站灯泡式水轮发电机的实际运行故障进行系统的分析,给出灯泡式水轮发电机的设计和运行规律及注意事项。

关 键 词:灯泡式水轮发电机 运行 故障分析 阻尼系统 定子 转子 飞来峡水电站
文章编号:1000-3983(2003)06-0013-04

Analysis on Operating Faults of Generator in Feilaixia Hydropower Station
DENG Dong ,SUN Yu-tian ,TAN Guo- wei ,LI Jin- xiang ,AN Zhi-hua. Analysis on Operating Faults of Generator in Feilaixia Hydropower Station[J]. Large Electric Machine and Hydraulic Turbine, 2003, 0(6): 13-17
Authors:DENG Dong   SUN Yu-tian   TAN Guo- wei   LI Jin- xiang   AN Zhi-hua
Affiliation:DENG Dong 1,SUN Yu-tian 2,TAN Guo- wei 1,LI Jin- xiang 2,AN Zhi-hua 2
Abstract:The actual operating faults of bulb type hydrogenerator in Feilaixia hydropower station were analyzed systematically ,and the design methods and operational rules were given in this paper.