首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of 2D simultaneous multi-slice and 3D GRASE readout schemes for pseudo-continuous arterial spin labeling of cerebral perfusion at 3 T
Authors:Nanjappa  Manjunathan  Troalen  Thomas  Pfeuffer  Josef  Maréchal  Bénédicte  Hilbert  Tom  Kober  Tobias  Schneider  Fabien C  Croisille  Pierre  Viallon  Magalie
Affiliation:1.Univ Lyon, UJM-Saint-Etienne, INSA, CNRS, UMR 5520, INSERM U1206, CREATIS, 42023, Saint-Etienne, France
;2.Siemens Healthcare SAS, Saint-Denis, France
;3.Siemens Healthcare GmbH, Application Development, Erlangen, Germany
;4.Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
;5.Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
;6.Signal Processing Laboratory (LTS 5), école Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
;7.Department of Radiology, University Hospital of Saint Etienne, 42055, Saint-Etienne, France
;8.University of Lyon, UJM-Saint-Etienne, TAPE EA7423, Saint-Etienne, France
;
Abstract:Objective

In this perfusion magnetic resonance imaging study, the performances of different pseudo-continuous arterial spin labeling (PCASL) sequences were compared: two-dimensional (2D) single-shot readout with simultaneous multislice (SMS), 2D single-shot echo-planar imaging (EPI) and multishot three-dimensional (3D) gradient and spin echo (GRASE) sequences combined with a background-suppression (BS) module.

Materials and methods

Whole-brain PCASL images were acquired from seven healthy volunteers. The performance of each protocol was evaluated by extracting regional cerebral blood flow (rCBF) measures using an inline morphometric segmentation prototype. Image data postprocessing and subsequent statistical analyses enabled comparisons at the regional and sub-regional levels.

Results

The main findings were as follows: (i) Mean global CBF obtained across methods was were highly correlated, and these correlations were significantly higher among the same readout sequences. (ii) Temporal signal-to-noise ratio and gray-matter-to-white-matter CBF ratio were found to be equivalent for all 2D variants but lower than those of 3D-GRASE.

Discussion

Our study demonstrates that the accelerated SMS readout can provide increased acquisition efficiency and/or a higher temporal resolution than conventional 2D and 3D readout sequences. Among all of the methods, 3D-GRASE showed the lowest variability in CBF measurements and thus highest robustness against noise.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号