Failure of a premix feeder line on a land-based gas turbine |
| |
Authors: | A Neidel C Yao |
| |
Affiliation: | (1) Siemens AG, Power Generation, G317QMW, Huttenstrasse 12, 10553 Berlin, Germany |
| |
Abstract: | A premix feeder line on a land-based gas turbine was found to be leaking, and the source of the leakage was traced back to
a crack in a pipe-to-fitting weld. The weld joined a coupling made from the X6CrNiMoTi17-12-2 austenitic stainless steel to
a type 316L austenitic stainless steel reducer. A root-cause assessment was conducted to determine the cause of the crack.
Evidence of fatigue and corrosive attack was found. Various factors that influence the susceptibility to corrosion and cracking,
such as heat tints, geometry of the weld, and surface finish of the component, are discussed. Recommendations are made for
corrective actions and failure prevention. |
| |
Keywords: | austenitic stainless steel corrosion fatigue gas turbine heat tint welding |
本文献已被 SpringerLink 等数据库收录! |
|