首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of different disinfection calculation methods using CFD
Authors:B.A. Wols  J.A.M.H. Hofman  W.S.J. Uijttewaal  L.C. Rietveld  J.C. van Dijk
Affiliation:1. KWR Watercycle Research Institute, 3430 BB Nieuwegein, The Netherlands;2. Delft University of Technology, 2600 GA Delft, The Netherlands;3. Waternet, 1108 AA Amsterdam, The Netherlands;1. School of Chemical Engineering and Technology, Sun Yat-sen University, China;2. Shenzhen Key Laboratory of Water Resource Application and Environmental Pollution Control, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen 518055, China;3. Department of Building and Environmental Engineering, Shenzhen Polytechnic, Shenzhen 518055, China;1. Hydro-environmental Research Centre, School of Engineering, Cardiff University, The Parade, Cardiff, UK;2. Technical & Industrial Division, Athens Technical College, Athens, GA, USA;1. Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Campus Box 7908, Raleigh, NC 27695-7908, USA;2. Department of Biological and Agricultural Engineering, North Carolina State University, Campus Box 7625, Raleigh, NC 27695, USA;3. Sensor Electronic Technology, Inc., 1195 Atlas Road, Columbia, SC 29209, USA
Abstract:Computational Fluid Dynamics combined with a particle tracking technique provides valuable information concerning residence times and contact times in chemical reactors. In drinking water treatment, for example an accurate estimation of the disinfection is important to predict the microbial safety. Ozone contactors are widely used for disinfection, but the complex geometry of the system causes suboptimal hydraulics and requires optimizations of the flow. This results in a lower ozone dosage, which may reduce the formation of unwanted disinfection-by-products and the consumption of energy. To that end disinfection needs to be calculated precisely, accounting for the complex hydraulics. Several calculation methods estimating the disinfection performance of ozone contactors were evaluated using Computational Fluid Dynamics. For an accurate disinfection prediction, the full distribution of ozone exposures (CT values) is needed, only a mean CT value or residence time distribution provides insufficient information for an accurate disinfection prediction. Adjustments to the geometry of the ozone contactor that reduce the short-circuit flows resulted in an increase in disinfection capacity, whereas the mean CT value remained the same. A sensitivity analysis with respect to the kinetics was conducted. The gain in disinfection capacity obtained by optimizing the hydraulics was significant for typical values used in practice.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号