首页 | 本学科首页   官方微博 | 高级检索  
     


Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer
Authors:Lena Stawreberg  Lars Nilsson
Affiliation:1. Department of Energy, Environmental and Building Technology, Karlstad University, SE 651 88 Karlstad, Sweden;2. Department of Chemical Engineering, Karlstad University, SE 651 88 Karlstad, Sweden;1. Doctoral School of Industrial Engineering, University of Padova, Stradella S. Nicola 3, Vicenza, 36100, Italy;2. Construction Technologies Institute, National Research Council, Corso Stati Uniti 4, Padova, 35127, Italy;1. Technische Universität Braunschweig, Institut für Thermodynamik, Hans–Sommer–Straße 5, 38106 Braunschweig, Germany;2. Miele & Cie KG, Carl–Miele–Straße 29, 33332 Gütersloh, Germany;3. LTX Simulation GmbH, Wohlfartstraße 21b, 80939 München, Germany;1. School of Mechanical Engineering, The University of Adelaide, SA 5005, Australia;2. Mechanical Engineering Department, University of Baghdad, Baghdad, Iraq;1. Multifunctional Equipment Integration Group, Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, TN, USA;2. Building Envelope Materials Research Group, Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, TN, USA;1. School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, Guangdong, China;2. Guangzhou Entry-exit Inspection and Quarantine Bureau, Guangzhou 510623, Guangdong, China
Abstract:The use of tumble dryers in households is becoming more common. Tumble dryers, however, consume large amounts of electric energy. A statistical model over the tumble dryer is created from a design of experiments. The model will be used to find the best settings for the power supply to the heater, the internal airflow and the external airflow in order to reach a high specific moisture extraction rate (SMER) and a low leakage ratio of water vapour. The aim also involves explaining the trends of the SMER and the leakage ratio based on the physics of the tumble dryer drying process. A statistically significant model, which can be used for improving the SMER and leakage ratio, was established from 19 experiments in a condensing tumble dryer. The results show that a high power supply to the heater, a high internal airflow and a low external airflow give the highest SMER values. This combination of settings also results in the largest leakage ratio values for the dryer. Leakage is most affected by the external airflow.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号