首页 | 本学科首页   官方微博 | 高级检索  
     


Mitigation of Single‐Point‐of‐Failure: Development of M127A1 White Star Illuminant Compositions Containing an Epoxy Binder System
Authors:Jesse J Sabatini  James M Raab  Ronald K Hann
Abstract:A replacement for the M127A1 hand‐held signal illuminant was developed to alleviate concerns associated with single‐point‐of‐failure. In addressing single‐point‐of‐failure, Laminac 4116/Lupersol binder system were replaced with Epon 813/Versamid 140 binder system. Powdered sodium nitrate was replaced with prilled sodium nitrate in the disclosed formulations to minimize hygroscopicity concerns associated with this oxidizer. The performance of the prilled sodium nitrate‐based formulations, their burning behaviors, and the sensitivities of the best performing illuminant toward various ignition stimuli are also described in detail.
Keywords:Pyrotechnics  Energetic materials  Illuminants  Binders  Sodium nitrate