首页 | 本学科首页   官方微博 | 高级检索  
     

汽轮机调节和保安系统改造后出现的问题及对策
引用本文:叶明. 汽轮机调节和保安系统改造后出现的问题及对策[J]. 电力建设, 2011, 32(4): 105-109. DOI: 10.3969/j.issn.1000-7229.2011.04.025
作者姓名:叶明
作者单位:中国国电九江发电厂,江西省,九江市,332000
摘    要:针对国电九江发电厂4号机调节和保安系统改造不完善,而发生静态试验中高、中压调速汽门的油动机开不足和无法正常地进行主汽门活动试验的问题,进行了原因分析,采取了切实可行的处理对策,消除了改造后出现的问题,取得了很好效果.

关 键 词:汽轮机  油动机  主汽门  静态试验  保安系统  改造

Problems Occurring after Renovation of the Controlling and Security Systems of Steam Turbine and Counter Measures
YE Ming. Problems Occurring after Renovation of the Controlling and Security Systems of Steam Turbine and Counter Measures[J]. Electric Power Construction, 2011, 32(4): 105-109. DOI: 10.3969/j.issn.1000-7229.2011.04.025
Authors:YE Ming
Affiliation:YE Ming (Guodian Jiujiang Power Plant,Jiujiang 332000,Jiangxi Province,China)
Abstract:Due to imperfect renovation of the unit 4's controlling and security systems of the Guodian Jiujiang Power Plant,some problems occurred such as the servomotor of medium-high and medium pressure governor steam valve was not sufficient in openness during the static test and the movable test of the main steam valve could not be carried out normally.An analysis was carried out on the causes and practical countermeasures were taken to eliminate the renovation-caused problems,which are proved to be effective.
Keywords:steam turbine  servomotor  main steam valve  static test  security system  renovation  