Accurate measurement method for the residues in liquefied petroleum gas (LPG) |
| |
Authors: | Quan Zhuang Junichi Yodotani |
| |
Affiliation: | a CANMET Energy Technology Center, Advanced Combustion Technology Group, 1 Haanel Drive, Ottawa, Ont., Canada K1A 1M1 b Cosmo Engineering Co., Ltd, 5-8, Higashi-Shinagawa, 2-Chome Shinagawa-Ku, Tokyo, 140-0002 Japan c Research and Development Center, Cosmo Oil Co., Ltd, 1134-2, Gongendo, Satte-shi, Saitama-ken 340-0193, Japan |
| |
Abstract: | A newly developed LPG residues measurement method is reported. First, residues in LPG is extracted into n-hexane. Then, the residues in n-hexane is analyzed by gas chromatography (GC). The method gives accurate results and good repeatability. It is powerful even at low concentration range where ASTM D2158-02 is not applicable. The method is easier to operate and takes less time compared with ASTM D2158-02 method. |
| |
Keywords: | LPG Propane Residues Extraction GC |
本文献已被 ScienceDirect 等数据库收录! |
|