无氧铜弯头开裂分析
引用本文:刘淑凤,王永兰,张智慧,刘安生,王书明.无氧铜弯头开裂分析[J].理化检验(物理分册),2008,44(9):504-506.
作者姓名:刘淑凤  王永兰  张智慧  刘安生  王书明
作者单位:北京有色金属研究总院分析测试所,北京100088
摘    要:无氧铜基器件在后期冷加工过程中在弯头处出现裂纹。对该失效件进行扫描电镜、金相和氧含量分析,并与未出现裂纹的正常件进行对比。结果表明,氧含量超标,存在大量的脆性相氧化亚铜,且材料内部仍留有部分残余应力,是失效的主要原因。

关 键 词:无氧铜  弯头  开裂  氧含量  氧化亚铜  残余应力

CRACKING ANALYSIS OF ELBOW OF OXYGEN-FREE COPPER
LIU Shu-feng,WANG Yong-lan,ZHANG Zhi-hui,LIU An-sheng,WANG Shu-ming.CRACKING ANALYSIS OF ELBOW OF OXYGEN-FREE COPPER[J].Physical Testing and Chemical Analysis Part A:Physical Testing,2008,44(9):504-506.
Authors:LIU Shu-feng  WANG Yong-lan  ZHANG Zhi-hui  LIU An-sheng  WANG Shu-ming
Affiliation:(Analysis and Testing Department, Beijing General Research Institute for Non-ferrous Metals, Beijing 100088, China)
Abstract:The crack of TU2 brazed elbow appeared during the hard-drawn process. It was investigated by means of SEM, metallography and oxygen content analysis. Results showed that the fracture was caused by higher content of O2, a large amount of Cu2 O and residual stress.