摘    要:介绍了用X射线荧光光谱法测定感光材料中的含银量,按含银量不同分段斜率输入法取代一次斜率输入法,较好地消除了基体效应影响,获得比较准确的分析结果。

关 键 词:X射线荧光光谱 感光材料 含银量 测定 分段斜率输入法
修稿时间:2001-08-02

Determination of Silver Content in Photographic Materials by X- Ray Fluorescence Spectrometry
Li Erhuai. Determination of Silver Content in Photographic Materials by X- Ray Fluorescence Spectrometry[J]. Image Technology, 2002, 0(1): 12-13
Authors:Li Erhuai
Affiliation:Shantou ERA Co.Ltd. Shantou 515064
Abstract:A method has been developed for determination of silver conternt in photographic materials by X-Ray Fluorescence Spectrometry. Input different portions of silver content range to get an optimum measuring slope and a parabola curve instead of the spectrometer original straight line to eliminate matrix effects, thus good precision and accurate analysis results were obtained.