首页 | 本学科首页   官方微博 | 高级检索  
     

太钢2号高炉破损情况分析
引用本文:姜全喜,冯世瑞,付俊生. 太钢2号高炉破损情况分析[J]. 山西冶金, 2006, 29(1): 50-52
作者姓名:姜全喜  冯世瑞  付俊生
作者单位:1. 太原钢铁(集团)有限公司钢炼铁厂,山西,太原,030003
2. 山西工程职业技术学院,山西,太原,030009
摘    要:针对2号高炉在两年半时间内高炉炉衬侵蚀严重、冷却器大量损坏的现象,停炉后对高炉本体破损情况进行调查分析,得出结论:无冷却自焙炭砖炉底已不再适应当前高炉高产、长寿的要求。

关 键 词:高炉  内衬  破损  分析
文章编号:1672-1152(2006)01-0050-03
收稿时间:2006-01-18
修稿时间:2006-01-18

Analysis on Breakage of the No.2 BF in TISCO.
JIANG Quanxi,FENG Shirui,FU Junsheng. Analysis on Breakage of the No.2 BF in TISCO.[J]. Shanxi Metallurgy, 2006, 29(1): 50-52
Authors:JIANG Quanxi  FENG Shirui  FU Junsheng
Abstract:Because of eroded the No.2 BF lining is seriously and most of the coolers are damaged within two and half years, we carry out the breakage analysis for the furnace body during shutdown and draw the conclusion that the bottom without cooling selfroasting carbon bricks can't meet the requirement of high output and long life of BF.
Keywords:blast furnace   lining   breakage   analysis
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号