首页 | 本学科首页   官方微博 | 高级检索  
     

复杂场景机械交错拼接遥感相机在轨相对定标
引用本文:闫钧华,倪 越,姜 宇,范君杰,张 寅.复杂场景机械交错拼接遥感相机在轨相对定标[J].仪器仪表学报,2021(5):131-139.
作者姓名:闫钧华  倪 越  姜 宇  范君杰  张 寅
作者单位:1. 南京航空航天大学空间光电探测与感知工业和信息化部重点实验室,2. 南京航空航天大学航天学院;3. 中国空间技术研究院遥感卫星总体部
基金项目:中央高校基本科研业务费(NJ2020021)、中央高校基本科研业务费(NT2020022)、国家自然科学基金(61705104)、江苏省自然科学基金(BK20170804)资助
摘    要:为了实现机械交错拼接型(TDICCD)遥感相机高频次、高精度相对辐射定标,本文提出一种面向复杂场景的在轨非均匀性校正方法。该方法在相机绕偏航轴旋转前后进行正交二次成像,利用所获取的偏航成像数据、常规成像数据分别对阵列内、阵列间探元进行相对定标;结合复杂场景宽辐射动态范围的特点,利用多点曲线拟合的方法实现相对定标参数解算,最终达到非均匀性校正的目的。利用仿真成像数据对均匀场景以及复杂场景进行相对辐射定标试验,结果表明,在非均匀场景中经复杂场景正交二次成像定标(OSICCS)后图像非均匀性NU系数相较于常用方法定标后图像非均匀性NU系数降低了0.499 1%以上,条纹条带噪声以及残余条带噪声得到有效去除。

关 键 词:交错拼接型相机  复杂场景  正交二次成像定标  在轨非均匀性校正

On-orbit relative calibration of mechanical interlaced stitching cameras in complex scenes
Yan Junhu,Ni Yue,Jiang Yu,Fan Junjie,Zhang Yin.On-orbit relative calibration of mechanical interlaced stitching cameras in complex scenes[J].Chinese Journal of Scientific Instrument,2021(5):131-139.
Authors:Yan Junhu  Ni Yue  Jiang Yu  Fan Junjie  Zhang Yin
Abstract:Proposes an on-orbit non-uniformity correction method for complex scenes, in order to achieve high-frequency and highprecision relative radiation calibration for mechanically interleaved stitching time delay integration charge coupled device ( TDICCD) cameras on orbit. This method performs orthogonal secondary imaging before and after the camera rotates around the yaw axis, and uses the side slither imaging data and conventional imaging data to respectively calibrate the probe elements within and between arrays. Combining the characteristics of the wide radiation dynamic range of complex scenes, the method of multi-point curve fitting is used to calculate relative calibration parameters and finally achieve the purpose of non-uniformity correction. By using simulation imaging data to perform relative radiometric calibration experiments on uniform scenes and complex scenes, these results show that the image non-uniformity NU coefficient which is processed by the orthogonal secondary imaging calibration of the complex scene(OSICCS) in the non-uniform scene is 0. 499 1% lower than that after the common calibration method, meanwhile, the noticeable striping artifact and residual noise are removed effectively.
Keywords:mechanical interlaced stitching cameras  complex scenes  orthogonal secondary imaging calibration  on-orbit non-uniformity correction
本文献已被 CNKI 等数据库收录!
点击此处可从《仪器仪表学报》浏览原始摘要信息
点击此处可从《仪器仪表学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号