不锈钢钢管开裂原因分析
引用本文:伍超群,朱峰. 不锈钢钢管开裂原因分析[J]. 理化检验(物理分册), 2008, 44(7): 373-374
作者姓名:伍超群  朱峰
作者单位:广州有色金属研究院,广州510650
摘    要:不锈钢钢管在加工成型过程中发生开裂。采用金相及电子探针等方法对不锈钢钢管的开裂原因进行了分析。结果表明,硫和锰元素含量超标,大量非金属硫化物夹杂物的存在造成不锈钢钢管的开裂。

关 键 词:不锈钢钢管  非金属夹杂物  断裂分析

FRACTURE ANALYSIS ON THE STAINLESS STEEL TUBE
WU Chao-qun,ZHU Feng. FRACTURE ANALYSIS ON THE STAINLESS STEEL TUBE[J]. Physical Testing and Chemical Analysis Part A:Physical Testing, 2008, 44(7): 373-374
Authors:WU Chao-qun  ZHU Feng
Affiliation:(Guangzhou Research Institute of Non-ferrous Metals, Guangzhou 510650, China)
Abstract:The stainless steel tube was broken in the moulding process was analyzed by metallography and EPMA methods. The results showed that the higher contents of sulphur and manganese and the existence of nonmetallic inclusion were the main factors causing the crack of stainless steel tube.
Keywords:Stainless steel tube  Non-metallic inclusion  Fracture analysis