首页 | 本学科首页   官方微博 | 高级检索  
     


Performance characteristics of mechanical foam‐breakers fitted to a stirred‐tank reactor
Authors:Satoshi Takesono  Masayuki Onodera  Masanori Yoshida  Kazuaki Yamagiwa  Akira Ohkawa
Abstract:In a stirred‐tank reactor (STR), a comparison of the performance of mechanical foam‐breakers: a six‐blade turbine (F‐B), a six‐blade vaned disk (V‐D), a two‐blade paddle (T‐P), a conical rotor (C‐R), a fluid‐impact dispersion apparatus (FIDA) and a rotating disk mechanical foam‐breaker (MFRD) was carried out using defined foaming media. The foam‐breaking ranges (relative to the gas superficial velocity, Ug) of the T‐P, C‐R and FIDA were inferior to that of the F‐B, V‐D and MFRD. The power consumption, Pkc, for foam‐breaking in the MFRD was the lowest among the F‐B, V‐D and MFRD. Operation of the F‐B and V‐D in the STR caused a considerable amount of liquid droplets from the collapsed foam to be entrained with the exhaust air. © 2002 Society of Chemical Industry
Keywords:stirred‐tank reactor  mechanical foam‐breaker  foam‐breaking power  liquid droplets