首页 | 本学科首页   官方微博 | 高级检索  
     

底层大开间框剪封底砌块组合墙房屋抗震性能分析
引用本文:蔡贤辉,张毅斌,张晶涛.底层大开间框剪封底砌块组合墙房屋抗震性能分析[J].沈阳建筑工程学院学报(自然科学版),2007,23(4):567-571.
作者姓名:蔡贤辉  张毅斌  张晶涛
作者单位:大连理工大学工业装备结构分析国家重点实验室 辽宁大连116024(蔡贤辉),辽宁省建筑设计研究院 辽宁沈阳110005(张毅斌),沈阳新大陆建筑设计有限公司 辽宁沈阳110003(张晶涛)
摘    要:目的应用振型分解反应谱法及弹塑性动力时程分析方法评价底层大开间框剪封底砌块组合墙房屋的抗震性能以及在地震区的应用可能性.方法以试设计的七度区6层房屋为例,采用分离化处理各抗侧单元的简化串并联动力分析模型,应用基于规范的振型分解反应谱法和以地震动记录作为输入的弹塑性动力时程分析方法进行结构的抗震计算,分析结构的薄弱楼层和变形集中问题,在概率统计的基础上分析结构的抗震性能,失效概率和可靠指标.结果过渡楼层为相对薄弱的楼层,强震下未见明显薄弱的楼层和变形集中问题,房屋结构具备良好的抗震性能和合适的抗震可靠指标.结论在七度区建造该类6层房屋是可行的.

关 键 词:封底砌块组合墙  底部框剪  大开间  抗震性能  可靠度
文章编号:1671-2021(2007)04-0567-05
修稿时间:2007-02-10

Seismic Performance Analysis of Bottom-Sealed Block Composite Masonry Buildings Supported by Frame/Shear-Wall Structure with Large Spacing in the First Storey
CAI Xianhui,ZHANG Yibin,ZHANG Jingtao.Seismic Performance Analysis of Bottom-Sealed Block Composite Masonry Buildings Supported by Frame/Shear-Wall Structure with Large Spacing in the First Storey[J].Journal of Shenyang Archit Civil Eng Univ: Nat Sci,2007,23(4):567-571.
Authors:CAI Xianhui  ZHANG Yibin  ZHANG Jingtao
Affiliation:1. State Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian 116023, China; 2. Institute of Architecture Design of Liaoning Province, Shenyang 110005, China; 3. Shenyang Xindalu Building Design Co., Ltd., Shenyang 110003, China
Abstract:The paper attempts to evaluate the seismic performance of bottom-sealed block composite masonry buildings supported by frame/shearwall structure with large spacing in the first storey and discuss the possibility of using them in seismic regions with intensity 7 of Chinese intensity scale.Based on the simplified series-parallel lumped model,with separate treatment of the different earthquake resistant elements as independent analysis elements,the code-based mode decomposition response spectrum method and inelastic time-history analysis by earthquake wave records are used.Statistical response data of a trail designed 6 story building are adopted for the discussions of the seismic performance,weak stories and displacement concentration problems.Failure probability and reliability index are estimated under the theory of seismic reliability.The transient story is a little weaker than others,but no obvious weak story or displacement concentration is found,however,under severe earthquake excitations.Favorable seismic performance and appropriate reliability index are discovered for the buildings.It is feasible to build similar 6-storey buildings in seismic region with intensity 7 of Chinese intensity scale.
Keywords:bottom-sealed block  composite masonry wall  large spacing  seismic performance  reliability
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号