首页 | 本学科首页   官方微博 | 高级检索  
     

箱式盲板阀故障原因分析及解决办法
引用本文:宋敬太,孙海涛,李少春. 箱式盲板阀故障原因分析及解决办法[J]. 包钢科技, 2014, 40(3): 14-15,54
作者姓名:宋敬太  孙海涛  李少春
作者单位:内蒙古包钢钢联股份有限公司燃气厂,内蒙古包头,014010;内蒙古包钢钢联股份有限公司燃气厂,内蒙古包头,014010;内蒙古包钢钢联股份有限公司燃气厂,内蒙古包头,014010
摘    要:文章主要针对包钢1#转炉煤气加压站,风机、电除尘出入口箱式盲板阀运行过程中,箱式盲板阀发生故障的现象、原因进行分析,并制定解决办法及措施,使箱式盲板阀运行正常。

关 键 词:箱式盲板阀  故障  解决办法

Analysis of Fault Reasons and Solutions of Box-type Blind Plate Valve
Affiliation:SONG Jing - Tai, SUN Hai - tao , LI Shao - chun ( Gas Plant of Steel Union Co. Ltd. of Baotou Steel (Group) Corp. , Baotou 014010, Nei Monggol, China )
Abstract:This paper mainly introduces the phenomena of fault and analyzes the reason of fault for box - type blind plate valve during its running process in entrance of fan and electrostatic precipitator in 1^# converter gas station in Baotou Steel. Also, this paper develops solutions and measures so as to ensure the normal operation of box - type blind plate valve.
Keywords:box- type blind plate valve  fault  solution