首页 | 本学科首页   官方微博 | 高级检索  
     

X射线荧光法测定催化裂化催化剂中含镍元素质量分数
引用本文:刘明霞,刘瑞强,孙伟,王亚红,高雄厚,张忠东,张海涛.X射线荧光法测定催化裂化催化剂中含镍元素质量分数[J].石化技术与应用,2013(3):232-234.
作者姓名:刘明霞  刘瑞强  孙伟  王亚红  高雄厚  张忠东  张海涛
作者单位:[1]中国石油兰州化工研究中心,甘肃兰州730060 [2]中国石油兰州石化公司油品储运厂,甘肃兰州730060 [3]新疆独山子天利实业总公司,新疆克拉玛依833600
基金项目:中国石油天然气集团公司资助项目(项目编号:2011B-2304-0304)
摘    要:采用浸渍法制备含镍标准试样,建立了利用X射线荧光法分析催化裂化(FCC)催化剂中含镍元素质量分数的方法,同时采用强度校正模式对该方法所得工作曲线进行基体校正。结果表明,稀土元素的存在影响X射线荧光法测定的准确性。采用基体校正后的X射线荧光法测定标准试样的含镍元素质量分数,其测定值与理论值的相对误差在±3%以内,相对标准偏差低于0.300%,表明该方法具有较高的精密度和准确度。

关 键 词:X射线荧光法  镍元素质量分数  催化裂化催化剂  强度校正

Determination of the mass fraction of Ni in fluid cracking catalyst by X- ray fluorescence spectrometry
LIU Ming-xia,LIU Rui-qiang,SUN Wei,WANG Ya-hong,GAO Xiong-hou,ZHANG Zhong-dong,ZHANG Hai-tao.Determination of the mass fraction of Ni in fluid cracking catalyst by X- ray fluorescence spectrometry[J].Petrochemical Technology & Application,2013(3):232-234.
Authors:LIU Ming-xia  LIU Rui-qiang  SUN Wei  WANG Ya-hong  GAO Xiong-hou  ZHANG Zhong-dong  ZHANG Hai-tao
Affiliation:LIU Ming - xia,LIU Rui - qiang ,SUN Wei ,WANG Ya - hong ,GAO Xiong - hou, ZHANG Zhong - dong,ZHANG Hai - tao(1. Lanzhou Petrochemical Research Center,PetroChina,Lanzhou 730060, China;2. Oil Storage and Transportation Plant of Lanzhou Petrochemical Company, PetroChina , Lanzhou 730060, China ; 3. Dushanzi Tianli Industrial Company ,Kelamayi 833600, China)
Abstract:X -ray fluorescence spectrometry for determining the mass fraction of Ni in fluid cracking catalyst was established with Ni containing standard samples made by impregnating method, and the working curve obtained by the method was corrected with intensity correction model. The results showed that the accuracy of the method was affected by rare earth elements. Using X - ray fluorescence spectrometry with matrix correction, the relative errors of the mass fraction of Ni between the measured and theoretical values were within + 3% ,the relative standard deviations were lower than 0.300%, implying this method had higher accuracy and precision.
Keywords:X- ray fluorescence spectrometry  mass fracion of Ni  fluid cracking catalyst  intensity correction