首页 | 本学科首页   官方微博 | 高级检索  
     

吸收塔浆液起泡溢流的原因分析及解决办法
引用本文:程永新. 吸收塔浆液起泡溢流的原因分析及解决办法[J]. 电力科学与工程, 2010, 26(10)
作者姓名:程永新
作者单位:中国电力工程顾问集团中南电力设计院,湖北,武汉,430071
摘    要:在石灰石-石膏湿法烟气脱硫(FGD)工艺系统中,吸收塔浆液溢流是较为常见的现象。为解决此问题的真正原因,着重从工艺品质、系统设计及运行维护等方面进行分析,并提出解决吸收塔浆液起泡溢流的办法,从而提高了FGD系统运行的稳定性。

关 键 词:湿法烟气脱硫  吸收塔浆液  泡沫  溢流  消泡剂  

Analysis and Solutions of Absorber Seriflux Foaming Overflow
Cheng Yongxin. Analysis and Solutions of Absorber Seriflux Foaming Overflow[J]. Power Science and Engineering, 2010, 26(10)
Authors:Cheng Yongxin
Affiliation:Cheng Yongxin(Central Southern China Electric Power Design Institute of China Power Engineering Consulting Group,Wuhan 430071,China)
Abstract:In the wet limestone-gypsum flue gas desulfurization(FGD) process system,the absorber seriflux overflowing is relatively common phenomenon.To solve the real cause of this problem,focus on quality from the process,system design and operation maintenance and other aspects analysis,and put forward the method to solve the question,and thereby improve the FGD system stability.
Keywords:wet flue gas desulfurization  absorption tower seriflux  foam  overflow  defoamer  