首页 | 本学科首页   官方微博 | 高级检索  
     

常顶挥发线波纹管膨胀节失效分析
引用本文:曾孟秋,王欣,陆磐谷. 常顶挥发线波纹管膨胀节失效分析[J]. 压力容器, 2004, 21(6): 46-49
作者姓名:曾孟秋  王欣  陆磐谷
作者单位:中石化股份公司上海高桥分公司,上海,200137
摘    要:通过对失效膨胀节的磁性检查、金相分析、断口形貌分析、腐蚀产物能谱分析、X射线衍射分析等检验 ,认为该膨胀节失效是由硫化氢导致的应力腐蚀开裂 ,并对其腐蚀环境因素、应力因素和材料因素进行阐述 ,并提出了预防建议

关 键 词:膨胀节  硫化氢  应力腐蚀开裂  预防
文章编号:1001-4837(2004)06-0046-04

Failure Analysis of Bellows Expansion Joint for Overhead Vapor Pipeline of Atmospheric Distillation Tower
ZENG Meng-qiu,WANG Xin,LU Pan-gu. Failure Analysis of Bellows Expansion Joint for Overhead Vapor Pipeline of Atmospheric Distillation Tower[J]. Pressure Vessel Technology, 2004, 21(6): 46-49
Authors:ZENG Meng-qiu  WANG Xin  LU Pan-gu
Abstract:On the base of the inspection and analysis of the magnetism inspection, metallographic examination, fracture appearance analysis, energy spectrum analysis and X-ray examination etc, it was concluded that the failure of expansion joint was caused by the stress corrosion cracking resulted from hydrogen sulfide. The paper also analyzed the factors of corrosion condition, stress and material. The corresponding prevention measures were suggested.
Keywords:expansion joint  hydrogen sulfide  stress corrosion cracking  prevention