摘    要:分析可能引起2号锅炉燃烧不稳定各种现象的原因,并进行针对性的检查、实验、测量和检修,在运行中采取相应的措施,较好地解决了燃烧不稳的问题。

关 键 词:锅炉  燃烧不稳  分析  措施
文章编号:1006-3986(2006)02-0015-03
收稿时间:2006-01-14
修稿时间:2006-01-14

Retrofit Measures for Unstable Combustion of No. 2 Boiler in Steel & Electricity Co. ,Ltd.
ZHANG Lu-jun. Retrofit Measures for Unstable Combustion of No. 2 Boiler in Steel & Electricity Co. ,Ltd.[J]. Hubei Electric Power, 2006, 30(2): 15-17
Authors:ZHANG Lu-jun
Affiliation:Wuhan Steel and Electricity Co. ,Ltd. ,Wuhan 430082,China
Abstract:The possible of unstable combustion phenomenon of No. 2 boiler were analyzed. Appropriate inspection, test as well as maintenance were performed. Corresponding measures were taken and the problem was solved completely.
Keywords:boiler   unstable combustion   analysis   measures