越南嘉兴水电厂发电机定子线圈损伤的修复
引用本文:兰生平,马梅霞,李庆. 越南嘉兴水电厂发电机定子线圈损伤的修复[J]. 红水河, 2012, 31(2): 53-55
作者姓名:兰生平  马梅霞  李庆
作者单位:南宁广发重工集团发电设备公司,广西南宁,530031
摘    要:越南广南省嘉兴水电厂1号机组定子线圈绝缘因事故损伤,文章对该定子线圈受损伤部位修复的技术处理方法作详尽的介绍。事实证明,用文中介绍的办法能在不吊出转子、不需把定子线圈全部取出的情况下,用最短的工期,可靠而有效地解决了定子线圈受损的问题。

关 键 词:定子线圈绝缘损伤  修复技术  耐压试验  越南嘉兴水电厂

Damage Repair for Generator Stator Coil of Zu Hung Hydropower Plant in Vietnam
LAN Sheng-ping , MA Mei-xia , Li Qing. Damage Repair for Generator Stator Coil of Zu Hung Hydropower Plant in Vietnam[J]. Hongshui River, 2012, 31(2): 53-55
Authors:LAN Sheng-ping    MA Mei-xia    Li Qing
Affiliation:(Nanning Good Fortune Heavy Industries Co.,Ltd.,Guangxi,Nanning,530031)
Abstract:The paper makes a detailed introduction to the technique for repairing the stator coil insulation damage of No.1 unit of Zu Hung hydropower plant in Quang Nam province of Vietnam.It is indicated that the suggested technique can reliably and effectively repair the damaged position within the shortest period without removing the stator and coil out of spiral cases.
Keywords:stator coil insulation damage  electric heating  epoxy resin  dressing  withstand voltage test  Zu Hung hydropower plant in Vietnam