首页 | 本学科首页   官方微博 | 高级检索  
     


Collapse test and moment capacity of the Ruytenschildt reinforced concrete slab bridge
Authors:Eva Lantsoght  Cor van der Veen  Ane de Boer  Dick Hordijk
Affiliation:1. Concrete Structures, Delft University of Technology, Delft, The Netherlands;2. Politecnico, Universidad San Francisco de Quito, Quito, Ecuador;3. Rijkswaterstaat, Department of Infrastructure – Section Bridges and Viaducts, Ministry of Infrastructure and the Environment, Utrecht, The Netherlands
Abstract:A large number of existing reinforced concrete solid slab bridges in the Netherlands are found to be insufficient for shear upon assessment. However, research has shown additional sources of capacity in slab bridges, increasing their total capacity and possibly changing their failure mode. Previous testing was limited to half-scale slab specimens cast in the laboratory. To study the full structural behaviour of slab bridges, testing to failure of a bridge is necessary. Research on load testing is carried out in order to develop load testing guidelines. In August 2014, a bridge was tested in two spans. The bridge was load tested, and additional cycles until yielding occurred in the reinforcement were added to the experiment. Though calculations with current design provisions showed that the bridge could fail in shear, the field test showed failure in flexure before shear. The unity check for flexure was determined. The experiment shows that the methods for rating of existing reinforced concrete slab bridges are conservative.
Keywords:Assessment  bridge tests  concrete slabs  field tests  flexural strength  shear strength
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号