Evaluation Model of Turbine Meter for Two-Phase Flow
Abstract:An evaluation model of a turbine meter has been developed to predict two-phase liquid velocity. The model considers the effects of blade configuration and void fraction distribution. In order to verify its applicability, experiments in single-phase and two-phase flows were performed and the model was compared with existing theories. This report describes the model and the experimental results on single-phase and two-phase flows.
Keywords:turbine meter  calibration  accuracy  evaluation model  two phase flow  gamma densitometer  void fraction