首页 | 本学科首页   官方微博 | 高级检索  
     


Method for Decision of Nuclear Reaction Model Parameters
Abstract:Application to decontamination is proposed of microwave discharge plasma in carbon tetrafluoride and oxygen mixture at atmospheric pressure. Preliminary cold experiments were conducted using cobalt oxide deposited on stainless steel plate. Fluorine atoms proved to be generated in high concentration in the plasma, which fluorinated the deposited metal oxide into volatile gaseous form. Upon plasma irradiation during about 200 s, the cobalt oxide deposit was removed to 100% from plate surface. Thermodynamic equilibrium calculations on CF4-O2 systems containing cobalt served to elucidate the mechanism of metal oxide removal by microwave discharge plasma, and similar calculations on systems containing actinides (U, Pu etc.) and lanthanides (La, Gd etc.) indicated that the process should be applicable also to the removal of these radioactive elements. It is concluded from the experimental and calculated results that decontamination is basically feasible with the proposed method of using microwave discharge plasma in a CF4-O2 system at atmospheric pressure.
Keywords:nuclear data evaluation  cross sections  emitted particle spectra  Bayes estimation  B-spline function  GNASH  level density parameters  yttrium 89  yttrium 90  zirconium 92  zirconium 93  niobium 92  niobium 93
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号