发电机氢气纯度下降原因分析及处理
引用本文:丁勇富,陈恳.发电机氢气纯度下降原因分析及处理[J].电站系统工程,2009,25(5).
作者姓名:丁勇富  陈恳
作者单位:云南大唐国际红河发电有限责任公司
摘    要:红河发电厂#1机300MW汽轮发电机组在2008下半年出现氢气纯度下降速度变快,靠频繁补氢置换维持的异常情况,通过阶段性SIS趋势分析以及现场试验,最终判断为氢侧密封油箱自动补排油浮球阀存在关闭不严问题,并制定现场措施解决了发电机氢纯度下降速度快的问题,保证了发电机氢系统的稳定运行。

关 键 词:氢冷发电机组  氢气纯度  下降

The Cause Analysis and Solution of Hydrogen-cooled Generator Hydrogen Purity Decline
DING Yong-fu,CHEN Ken.The Cause Analysis and Solution of Hydrogen-cooled Generator Hydrogen Purity Decline[J].Power System Engineering,2009,25(5).
Authors:DING Yong-fu  CHEN Ken
Affiliation:DING Yong-fu,CHEN Ken
Abstract:No.1 turbogenerator of Honghe Power Generation CO., Ltd appear hydrogen purity decline speed up in the second half of 2008, which need frequent replacement to keep. Through on-site test, the conclusion is the existence of floating ball valve closed lax problems. Measures are taken to address the scene of the power generator hydrogen purity rate of decline quick question, to ensure that the generator hydrogen system for stable operation.
Keywords:hydrogen-cooled generator  hydrogen purity  decline  