首页 | 本学科首页   官方微博 | 高级检索  
     

200MW机组启停过程中节能优化试验研究
引用本文:李维东.200MW机组启停过程中节能优化试验研究[J].工程与试验,2014(3):33-35.
作者姓名:李维东
作者单位:大唐长春第二热电有限责任公司,吉林 长春,130031
摘    要:本文阐述了某热电有限责任公司6×200MW超高压机组近年来的启停节能状况。从设备改造前后试验对比和设备启停方式分析了影响机组启停的经济因素,提出了机组启停节能降耗的优化运行技术措施。

关 键 词:热电机组  节能降耗  技术措施

Experimental Study on Optimization of Energy Saving in Process of 200MW Unit Start-Stop
Li Weidong.Experimental Study on Optimization of Energy Saving in Process of 200MW Unit Start-Stop[J].ENGINEERING & TEST,2014(3):33-35.
Authors:Li Weidong
Affiliation:Li Weidong (Changchun No. 2 Co-generation Power Co., Ltd. Changchun 130031, Jilin, China)
Abstract:The energy consumption of the Changchun No. 2 Co-generation Power Co. , Ltd. (referred to the No. 2 heat) in 6 × 200MW EHV units start-stop is described in this paper. According to the experimental comparison before and after the equipment transformation and the start- stop mode of the equipment, the economic factors which influence the unit start-stop are analyzed, and the technical measures to reduce the energy consumption in the process of unit startstop are put forward.
Keywords:EHV units  energy consumption  technical measures