首页 | 本学科首页   官方微博 | 高级检索  
     

低弹模高抗渗性防渗墙混凝土配合比设计研究
引用本文:王馨玉,任虎平.低弹模高抗渗性防渗墙混凝土配合比设计研究[J].江苏建筑,2012(1):76-77,98.
作者姓名:王馨玉  任虎平
作者单位:1. 镇江市建设工程管理处,江苏镇江,212000
2. 镇江市亿鑫城建有限公司,江苏镇江,212000
摘    要:文章结合乐眉水库坝体防渗墙混凝土试验研究,通过正交试验,分析了水胶比、膨润土掺量、引气剂用量3因素对防渗墙混凝土抗压强度、劈裂抗拉强度、弹性模量和渗透系数的影响。研究结果表明:水胶比和引气剂掺量是影响防渗墙混凝土抗压强度、劈裂抗拉强度和弹性模量的关键因素,水胶比和膨润土掺量是影响防渗墙混凝土渗透系数的关键因素。从满足抗压强度(≥5 MPa)和弹性模量(≤2 000 MPa)和良好的抗渗性能等方面来看,防渗墙混凝土的最佳配比为:膨润土掺量50%,水胶比0.9,引气剂用量0.02%。

关 键 词:防渗墙混凝土  力学性能  渗透系数  配合比设计

Mix Proportion Design and Study of the Stick up to Leakage Concrete of Dam Wall with Low Elastic Modulus and High Anti-Permeability
WANG Xin-yu,REN Hu-ping.Mix Proportion Design and Study of the Stick up to Leakage Concrete of Dam Wall with Low Elastic Modulus and High Anti-Permeability[J].Jiangsu Construction,2012(1):76-77,98.
Authors:WANG Xin-yu  REN Hu-ping
Affiliation:Combined with the research of the cutoff wall concrete of Guangxi Lemei Reservoir and by using orthogonal test,this paper analyzes the influence of the water-binder ratio,bentonite mixing amount and air-entraining agent amount to the compressive strength,crack and tensile strength,elastic modulus and permeability coefficient of the cutoff wall concrete.The results of the study show that the water-binder ratio and air-entraining agent amount are the key factors influencing the compressive strength,crack and tensile strength,elastic modulus of the cutoff wall concrete.The water-binder ratio and bentonite mixing amount are the key factors of the permeability coefficient.From the aspect of meeting the compressive strength(≥5 MPa),elastic modulus(≤2000 MPa) and good anti-permeability,the best proportion of cutoff wall concrete is: 50% of bentonite mixing amount,0.9 of water-binder ratio and 0.02% of air-entraining agent amount.
Abstract:Combined with the research of the cutoff wall concrete of Guangxi Lemei Reservoir and by using orthogonal test,this paper analyzes the influence of the water-binder ratio,bentonite mixing amount and air-entraining agent amount to the compressive strength,crack and tensile strength,elastic modulus and permeability coefficient of the cutoff wall concrete.The results of the study show that the water-binder ratio and air-entraining agent amount are the key factors influencing the compressive strength,crack and tensile strength,elastic modulus of the cutoff wall concrete.The water-binder ratio and bentonite mixing amount are the key factors of the permeability coefficient.From the aspect of meeting the compressive strength(≥5 MPa),elastic modulus(≤2000 MPa) and good anti-permeability,the best proportion of cutoff wall concrete is: 50% of bentonite mixing amount,0.9 of water-binder ratio and 0.02% of air-entraining agent amount.
Keywords:cutoff wall concrete  mechanical properties  permeability coefficient  mix proportion design
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号