摘    要:介绍了增安型和隔爆型Ex电缆引入装置的基本结构和主要性能特点,归纳了EX电缆引入装置安装方便快捷、防护性能优良等优点,有利于防爆电气产品用户更好地应用。

关 键 词:Ex电缆  引入装置  特点
文章编号:1004-9118(2006)01-0004-02
收稿时间:2005-12-29
修稿时间:2005-12-29

Introduction on the Design Features of Two Types of Ex Cable Entries
XUE Fu-lian. Introduction on the Design Features of Two Types of Ex Cable Entries[J]. Electric Explosion Protection, 2006, 0(1): 4-5
Authors:XUE Fu-lian
Affiliation:Shenyang Liaozhong Chemical Plant,Liaoning, Liaozhong county, 110200, China
Abstract:This article describes in details the basic structure and main performance and features of two types of Ex cable entries,Ex d and Ex e.Meanwhile,the advantages of the two types of Ex cable entries,such as convenient installation and good protection property,are summed up comparatively.