首页 | 本学科首页   官方微博 | 高级检索  
     

二滩水电厂水导轴承甩油原因分析及改造
引用本文:徐文峰,隽军峰,赵海英.二滩水电厂水导轴承甩油原因分析及改造[J].水电站机电技术,2005,28(1):3-4.
作者姓名:徐文峰  隽军峰  赵海英
作者单位:二滩水力发电厂,四川,攀枝花,617000;二滩水力发电厂,四川,攀枝花,617000;二滩水力发电厂,四川,攀枝花,617000
摘    要:二滩水力发电厂水导从首台机第一次启动就一直存在严重的甩油问题。经其对甩油做了定性、定量试验,准确的分析、判断出了甩油的原因。提出了切实可行的改造方案.由GYBD负责施工首先在5号机组获得成功。其它机组陆续采用该方案,水导油槽甩油问题得以根治。

关 键 词:水导  甩油  分析  改造

Analysis and reformation against oil leakage of turbine guide bearing in Ertan Hydropower Plant
Authors:Xu Wenfeng  Juan Junfeng  Zhao Haiying
Abstract:Serious oil leakage befell the turbine guide bearing during star-up of the first unit. By qualitative and quantitative test and analysis, the exact cause of oil leakage was found and a feasible reformation scheme was proposed. At first, the scheme was put in practice to Unit 5 by GYBD successfully. Afterward, it was adopted in all other units and the oil leakage problem was solved thoroughly.
Keywords:turbine guide bearing  oil leakage  analysis  reformation
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号