首页 | 本学科首页   官方微博 | 高级检索  
     

沾污对取样含水率计的影响及传感器的设计原则
引用本文:刘兴斌 庄海军. 沾污对取样含水率计的影响及传感器的设计原则[J]. 测井技术, 1995, 19(1): 54-57,72
作者姓名:刘兴斌 庄海军
作者单位:哈尔滨工业大学精仪系,大庆生产测井研究所
摘    要:在低频范围内(100kHz之内)自来水和地层水都是电的良导体。由此出发可以推论:在低流速下取样式电容含水率诗的主要测量误差来自于油对内电极的沾污,实验证实了这一结论。本文对沾污导致的误差进行了定量分析,并提出了传感器电极的设计原则。

关 键 词:含水率计 测量误差 传感器 电极 生产井 采油井

The Effects of Oil Contamination on Water Cut Meter and the Design Principle for the Sensor
Liu Xingbin et al.. The Effects of Oil Contamination on Water Cut Meter and the Design Principle for the Sensor[J]. Well Logging Technology, 1995, 19(1): 54-57,72
Authors:Liu Xingbin et al.
Affiliation:Liu Xingbin et al.
Abstract:In low frequency range (within 100kHz), both tap-water used for calibrationand formation water are good electric conductors. Based on this fact, it is predictedthat the output drift of the sample type capacitance water cut meter is caused by inside electrode being contaminated with oil. The prediction has been proved by experiment. In present work, the error caused by oil contamination is analysed quantitatively. The design principle for the sensor is also proposed.
Keywords:water cut meter measurement error quantitative analysis sensor electrode  