首页 | 本学科首页   官方微博 | 高级检索  
     

二甲苯加热炉炉管失效分析
引用本文:高丽岩.二甲苯加热炉炉管失效分析[J].石油化工设备技术,2012,33(2):18-21,3.
作者姓名:高丽岩
作者单位:中国石油化工股份有限公司天津分公司装备研究院,天津,300271
摘    要:二甲苯加热炉对流段1根遮蔽管发生泄漏着火。对该炉管进行全面检测和分析,判断出其失效原因是炉管存在原层烟灰沉积物,在炉子停工期间吹灰器蒸汽管滴水,造成管外壁发生垢下腐蚀。

关 键 词:炉管  失效  垢下酸腐蚀

FAILURE ANALYSIS OF FURNACE TUBE AND ITS LIFE ASSESSMENT
Gao Liyan.FAILURE ANALYSIS OF FURNACE TUBE AND ITS LIFE ASSESSMENT[J].Petro-Chemical Equipment Technology,2012,33(2):18-21,3.
Authors:Gao Liyan
Affiliation:Gao Liyan(Equipment Research Institute of SINOPEC Tianjin Company,Tianjin,300271)
Abstract:Leakage occurred in a shield tube in the convection section of xylene furnace and caused fire accident.A comprehensive monitoring and analysis on this tube was carried out.And it was determined that the failure was caused by flue gas fouling sediment.During the shutdown period of the furnace,steam dripping in the soot blower resulted in the corrosion under scale on the external wall of the tube.
Keywords:Furnace tube  Failure  Life assessment
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号