摘    要:为了去除某净水厂突发超标的锰和色度,采取了在预氧化接触池投加氯的措施,实际运行结果表明,该方法效果好、工艺简单、易于操作。同时也查找了原水锰的来源,提出了应对建议,供净水厂设计运行时参考。

关 键 词:地表水源  锰超标  预氧化  液氯  应急  

Emergency treatment of the manganese pollution accident in water resource
Qiang Changlin,Sun Yuhua. Emergency treatment of the manganese pollution accident in water resource[J]. Water & Wastewater Engineering, 2011, 0(10)
Authors:Qiang Changlin  Sun Yuhua
Affiliation:Qiang Changlin,Sun Yuhua(Hefei Water Supply Group Co.,Ltd.,Hefei 230011,China)
Abstract:The chlorine dosing measurements were used in pre-oxidation contact tank to remove the unexpected more manganese and chromaticity in water treatment plant.The practical results showed these measures performed well,and the process was simple and easy to operate.The source of the manganese in water resource was also found,and some suggestions were offered for the references of water treatment plant design.