修稿时间:2005-01-052005-05-17

Experimental Study of Two-phase Flows under the Composite Fluidization of Desulfurizer Straight/rotating Flows in a Circulating Fluidized Bed
HAO Xiao-wen,MA Chun-yuan,HUANG Sheng-zhu,ZHANG Li-qiang. Experimental Study of Two-phase Flows under the Composite Fluidization of Desulfurizer Straight/rotating Flows in a Circulating Fluidized Bed[J]. Journal of Engineering for Thermal Energy and Power, 2005, 20(5): 497-500,505
Authors:HAO Xiao-wen  MA Chun-yuan  HUANG Sheng-zhu  ZHANG Li-qiang
Abstract:The Venturi straight-flow fluidization speed of a circulating fluidized bed desulfurizer will change with a change in boiler load.This has a negative influence on desulfurization efficiency.The authors have come up with a straight/rotating flow composite fluidization mode,which can adapt to boiler load variation.Moreover,a PDA(Phase Doppler Anemometer) measurement system was employed to test the gas-solid two-phase flow field under this kind of fluidization mode.As a result,the gas-solid tangential speed and concentration distribution were obtained under the condition of a change in swirl airflow and an imaginary tangential radius in the circulating fluidized bed.Test results indicate that the tangential velocity in the composite-fluidization circulating fluidized bed will increase with an increase in radius and the gas-solid tangential slip speed is higher than that of the straight flow fluidization.There will also be an increase in concentration in the desulfurizer and a higher intensity in internal circulation,resulting in a corresponding increase in desulfurizaion efficiency.
Keywords:circulating fluidized bed  composite fluidization  tangential velocity  internal circulation
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《热能动力工程》浏览原始摘要信息
点击此处可从《热能动力工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号