首页 | 本学科首页   官方微博 | 高级检索  
     


Investigation of the strength of thermal transducers
Authors:S I Yakovenko  A P Guk  V I Lakh  V N Kryzhanovskii
Abstract:
1.  The temperature-time relationship of the allowable mechanical loads of a thermal transducer protection tube was established.
2.  For a preliminary evaluation of the strength of a thermal transducer in relation to service time it is necessary to use the temperature relationship of the modulus of elasticity or of the stress-rupture strength of the materials used.
3.  Failure of the protection tube of a thermal transducer in long high-temperature loading occurs as the result of development of pores primarily at grain boundaries.
Electric Temperature Measurement Special Design Office, Lvov. Translated from Problemy Prochnosti, No. 12, pp. 111–113, December, 1988.