Abstract: | 1. |
The temperature-time relationship of the allowable mechanical loads of a thermal transducer protection tube was established.
| 2. |
For a preliminary evaluation of the strength of a thermal transducer in relation to service time it is necessary to use the temperature relationship of the modulus of elasticity or of the stress-rupture strength of the materials used.
| 3. |
Failure of the protection tube of a thermal transducer in long high-temperature loading occurs as the result of development of pores primarily at grain boundaries.
|
Electric Temperature Measurement Special Design Office, Lvov. Translated from Problemy Prochnosti, No. 12, pp. 111–113, December, 1988. |