摘    要:全进口的500kV六氟化硫封闭式组合电器(GIS)的大修经验和工艺,对岩滩水电站检修人员还属于空白,此次能够成功地在现场对进口的2组断路器操作机构设备进行大修,解决了岩滩水电站的全进口GIS设备存在安全隐患问题,更为岩滩水电站其余GIS设备检修提供决策依据和经验。

关 键 词:断路器  现场检修  岩滩水电站

Introduction to In Situ Overhaul of 500kV GIS Circuit Breaker
QIN Guang-yi. Introduction to In Situ Overhaul of 500kV GIS Circuit Breaker[J]. Hongshui River, 2010, 29(2): 78-83
Authors:QIN Guang-yi
Affiliation:QIN Guang-yi (Datang Yantan Hydropower Co., Ltd, Dahua 530811)
Abstract:The maintenance personnel of Yantan Hydropower Station had no experience and understanding of overhaul of totally imported 500kV SF6 GIS. However, the latest successful overhaul of operating device of two groups of imported circuit breaker in situ not only solves potential safety problems of totally imported GIS equipment of the station, but also provides reference and experience for overhaul of other GIS equipment.