Design Study of Top Lid with Clamp Structure in JT-60SA Cryostat |
| |
Authors: | Shigetoshi NAKAMURA Yusuke K.SHIBAMA Kei MASAKI Akira SAKASAI |
| |
Affiliation: | Japan Atomic Energy Agency, Mukouyama 801-1, Naka, Ibaraki 311-0193, Japan |
| |
Abstract: | JT-60SA is a fully superconducting coil tokamak upgraded from the JT-60U. This paper focused on the integrity of the top lid of cryostat in JT-60SA. The design requirement for the cryostat in normal operations is to achieve vacuum insulation of 10¡3 Pa, and the top flange of the top lid is lightly welded onto its body flange. The weld is tensile-loaded by bending deformation of the top lid due to vacuum pressure of external 0.1 MPa. This weld integrity is evaluated with tensile-load reduction, which results in clamp reinforcement. The structural integrity of the top lid is validated. |
| |
Keywords: | clamp vacuum insulation top lid cryostat JT-60SA |
本文献已被 CNKI 万方数据 等数据库收录! |