首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of image quality using 1 : 1 pitch and 1.5 : 1 pitch helical CT in children: a comparative study
Authors:A Vade  TC Demos  MC Olson  P Subbaiah  RC Turbin  K Vickery  K Corrigan
Affiliation:Department of Radiology, Loyola University Medical Center, 2160 S. First Avenue, Maywood, IL 60153, USA.
Abstract:OBJECTIVE: The objective of this study was to compare the quality of 1 : 1 and 1.5 : 1 pitch helical contrast-enhanced thoracic and abdominal CT images in children who cannot cooperate for breath holding. MATERIALS AND METHODS: This is a retrospective study of 33 contrast-enhanced CT examinations in 11 children of 0-4 years of age. All children had an initial CT study using 1 : 1 pitch helical scanning followed over the next 6-36 months by one to four CT examinations with 1.5 : 1 pitch. Radiation dose with the two techniques was measured with a pencil ionization chamber. RESULTS: The two techniques provided comparable overall image quality. There was 33 % less radiation dose with 1.5 : 1 pitch helical scanning. CONCLUSION: The 1.5 : 1 pitch helical CT provides comparable quality images and a smaller radiation dose than 1 : 1 pitch in examining children aged 0-4 years.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号